TP3-2131A024M | Door Safety Sensor | Công tắc cửa an toàn TP3-2131A024M | Euchner Vietnam

(0 đánh giá)

TP3-2131A024M

Eucher Vietnam I Greentech Vietnam

12 tháng

TP3-2131A024M | Door Safety Sensor | Công tắc cửa an toàn TP3-2131A024M | Euchner Vietnam

Features

  • Auxiliary release on the front
  • With door monitoring contact
  • Increased horizontal overtravel

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Increased overtravel for horizontal approach direction

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

Guard locking type

TP3 Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

Switching element

2131 Slow-action switching contact 2 NC Figure + 1 NO + 1 NC (door monitoring contact)

Auxiliary release

Is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Approvals

Zulassung DGUVZulassung c_UL_us LISTEDZulassung SIBEZulassung CCC

Mechanical figures and environment

Housing material Reinforced thermoplastic
Ground  
Net 0,5 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation position Any
Number of door position positively driven contacts 2
Number of NC contacts 1
Number of NO contacts 1
Connection  
3 x M20 x 1.5
Approach speed  
max. 20 m/min
Actuation frequency 1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 1300 N
Locking force FZh(in accordance with GS-ET-19) 1000 N
Retention force 10 N
Extraction force 20 N
Actuating force 10 N

Electrical connection ratings

Thermal rated current Ith 4 A
Utilization category acc. to EN 60947-5-1  
AC-15 4A 230V
DC-13 4A 24V
Solenoid operating voltage  
AC/DC 24 V  -15% ... +10%
Short circuit protection according to IEC 60269-1  
(Fuse) 4A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
switching voltage  
Min. at 10mA 12 V
Switching current  
Min. at 24V 1 mA
Power consumption 8 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm²

Reliability values according to EN ISO 13849-1

  Monitoring of guard locking and the safety guard position
B10d 3 x 106
  Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHd Depending on external control of guard locking

In combination with Actuator BETAETIGER-P-GT

Mechanical figures and environment

Overtravel A B C D E 2 mm
Overtravel K L M N 1,5 mm

In combination with Actuator BETAETIGER-P-GNT

Mechanical figures and environment

Overtravel A B C D E 7 mm
 

769 ARTICLE(S) FOUND